KEY TAKEAWAYS

  • Microperimetry measures macular sensitivity to light stimuli while imaging the retina at the tested location in real-time.
  • Order microperimetry when subjective symptoms outpace measured visual acuity, or when reading or low-light function is slipping without a clear structural correlate.
  • The FDA has accepted microperimetry as a functional outcome measure in inherited retinal disease trials, and it was a prespecified functional endpoint in the GALE open-label extension data for pegcetacoplan (Syfovre, Biogen).

Microperimetry, also known as fundus-controlled perimetry, is a clinical technique that measures macular sensitivity to light stimuli while simultaneously imaging the retina at the tested location in real-time.1 It bridges retinal structure and function by quantifying point-by-point sensitivity in decibels (dB). Like standard automated visual field perimetry, it measures a hill of vision, but with a key advantage: Continuous eye tracking ensures each stimulus lands on the intended retinal coordinate (Figure). Because retinal landmarks are co-registered across sessions, the same points can be retested over time, which makes the test well suited to longitudinal follow-up.

<p>Figure. This image depicts a microperimetry sensitivity map overlaid on a central macular atrophic lesion. The black loci indicate absolute scotoma (0 dB), with progressively higher retinal sensitivity represented by red (1-5 dB), orange (6-15 dB), yellow (16-20 dB), and green (21-30 dB) test points. The blue markers denote fixation points and the fixation target. (This figure is a schematic illustration generated for demonstrative purposes and is not derived from patient-specific microperimetry data.)</p>

Click to view larger

Figure. This image depicts a microperimetry sensitivity map overlaid on a central macular atrophic lesion. The black loci indicate absolute scotoma (0 dB), with progressively higher retinal sensitivity represented by red (1-5 dB), orange (6-15 dB), yellow (16-20 dB), and green (21-30 dB) test points. The blue markers denote fixation points and the fixation target. (This figure is a schematic illustration generated for demonstrative purposes and is not derived from patient-specific microperimetry data.)

WHEN TO CONSIDER MICROPERIMETRY

Visual acuity evaluates only the central 1° to 2° of the fovea and can miss noncentral disease entirely. For example, a patient with nonsubfoveal geographic atrophy (GA) can have a VA of 20/20 on the Snellen chart and still struggle to read a menu in a dim restaurant. Microperimetry, by testing more widely across the macula, can quantify peripheral functional deficit. It’s often used in research and clinical trials and is particularly useful for monitoring foveal-sparing disorders and drug toxicity (Table). 

In GA and intermediate AMD, retinal sensitivity at the junctional zone declines long before visual acuity changes. In a post-hoc analysis of the phase 3 OAKS trial, microperimetry within 250 µm of the GA lesion border showed decreased loss of retinal sensitivity and fewer new absolute scotomatous points in eyes treated with pegcetacoplan (Syfovre, Biogen) compared with sham, supporting the junctional zone as a functional biomarker of disease activity.3,4 Grid geometry is particularly important for GA because the standard 10-2 microperimetry grid uses 68 equidistant points spaced roughly 580 μm apart, which may be too coarse to show benefit in a 2-year GA study, as average radial GA growth is only 100-300 µm/year.

Microperimetry can also help us monitor inherited retinal diseases (IRDs) because visual acuity is frequently preserved while peripheral and paracentral function deteriorates. Characterizing the preferred retinal locus may inform low-vision rehabilitation for patients with Stargardt disease, retinitis pigmentosa, and cone dystrophies.5,6 

MICROPERIMETRY TERMINOLOGY

  • Microperimetry: Measures point-to-point macular light sensitivity using fundus imaging and active eye tracking.
  • Retinal Sensitivity Threshold: Minimum detectable light stimulus at a specific locus, measured in decibels.
  • Preferred Retinal Locus: Healthy, eccentric retinal area adopted as the new visual center when the fovea is damaged.
  • Fixation Stability: Measure of gaze steadiness during testing, typically categorized as stable, relatively unstable, or unstable.
  • Absolute Scotoma: Retinal area with profound sensitivity loss; unable to perceive maximum-intensity stimuli.
  • Relative Scotoma: Retinal area with reduced, but not completely absent, light sensitivity.
  • Dynamic Range: The spectrum of stimulus intensities a specific device can produce.

Point-by-point sensitivity maps help clinicians localize and track scotoma growth to counsel patients on expected disease trajectory. This has made microperimetry a common FDA-accepted functional endpoint in IRD gene therapy trials, where treatment effects are often localized to the injection site.7,8 For example, macular telangiectasia type 2 may produce a temporal paracentral scotoma worth tracking on serial testing.9 A treated macula (eg, resolved central serous chorioretinopathy, regressed choroidal neovascularization, repaired macular hole) may also benefit from microperimetry testing. When a patient reports vision difficulties despite anatomic success, microperimetry may identify the functional cause. 

Hydroxychloroquine screening is another reason to order the test because parafoveal sensitivity loss can appear before bull’s-eye changes are visible on structural imaging.8

Reproducibility is the strongest argument for using microperimetry in long-term follow-up. Because the tracker places each stimulus at the same retinal location on every visit, the test-retest noise floor is well below that of standard automated perimetry. A reliability analysis of the junctional zone approach using OAKS data showed excellent agreement for both mean sensitivity and scotomatous point counts, supporting its use as a trial endpoint.11 In GA, mean sensitivity and absolute scotoma counts decline measurably over 6 to 12 months, often before expansion is visible on fundus autofluorescence or OCT.2 A drifting preferred retinal locus, or fixation that downgrades between visits, may be a warning that the fovea is under threat.12 

TESTING LIMITATIONS

Microperimetry requires sustained patient attention, and the time for testing per eye depends on the pattern and thresholding strategy. In the OAKS trial, the mean time for testing was approximately 8 minutes per eye,3 which can be difficult for some patients. The dynamic range also has a ceiling effect; on some devices, early functional loss remains undetectable at 36 dB, while severe-to-absolute scotomas of varying depth all register near zero.

ADVANCES ON THE HORIZON

AI algorithms that co-register OCT features with microperimetry sensitivity points are under investigation.13-15 The goal is biomarker-targeted testing that places stimuli directly on the at-risk junctional retina, making the test a more sensitive longitudinal endpoint. 

The regulatory landscape is also shifting. The FDA has accepted microperimetry as a functional outcome measure in IRD trials,16 and it is a secondary endpoint in trials of RPGR-targeted gene therapy for X-linked retinitis pigmentosa.7,8 In GA, the GALE open-label extension data for pegcetacoplan showed an 18% reduction in new scotomatous points at 36 months with monthly dosing (P = .0156)—the first prespecified functional endpoint to show benefit for an approved GA therapy.17

The shift from research tool to standard trial endpoint is here, and microperimetry’s clinical utility will soon follow.

1. Markowitz SN, Reyes SV. Microperimetry and clinical practice: an evidence-based re-view. Can J Ophthalmol. 2013;48(5):350-357. doi.org/10.1016/j.jcjo.2012.03.004

2. Wu Z, Ayton LN, Luu CD, Guymer RH. Longitudinal changes in microperimetry and low luminance visual acuity in age-related macular degeneration. JAMA Ophthalmol. 2015;133(4):442-448. doi.org/10.1001/jamaophthalmol.2014.5963

3. Chakravarthy U, Schwartz R, Guymer RH, et al. Visual function benefit after treatment with pegcetacoplan: microperimetry analysis from the phase 3 OAKS trial. Am J Ophthalmol. 2025;273:119-129. doi.org/10.1016/j.ajo.2025.02.012

4. Heier JS, Lad EM, Holz FG, et al. Pegcetacoplan for the treatment of geographic atrophy secondary to age-related macular degeneration (OAKS and DERBY): two multicentre, randomised, double-masked, sham-controlled, phase 3 trials. Lancet. 2023;402(10411):1434-1448. doi.org/10.1016/S0140-6736(23)01520-9

5. Schönbach EM, Janeschitz-Kriegl L, Strauss RW, et al. The progression of Stargardt disease using volumetric hill of vision analyses over 24 months: ProgStar Report No. 15. Am J Ophthalmol. 2021;230:123-133. doi.org/10.1016/j.ajo.2021.04.015

6. Buckley TMW, Jolly JK, Josan AS, Wood LJ, Cehajic-Kapetanovic J, MacLaren RE. Clinical applications of microperimetry in RPGR-related retinitis pigmentosa: a review. Acta Ophthalmol. 2021;99(8):819-825. doi.org/10.1111/aos.14816

7. von Krusenstiern L, Liu J, Liao E, et al; XIRIUS Part 1 Study Group and XOLARIS Study Group. Changes in retinal sensitivity associated with cotoretigene toliparvovec in X-linked retinitis pigmentosa with RPGR gene variations. JAMA Ophthalmol. 2023;141(3):275-283. doi.org/10.1001/jamaophthalmol.2022.6254

8. Josan AS, Raji S, MacLaren RE. Approval of retinal gene therapies in the US and Europe based on visual acuity and microperimetry. Expert Rev Ophthalmol. 2025;20(3):127-132. doi.org/10.1080/17469899.2025.2487544

9. Wong EN, De Soyza JDA, Mackey DA, Constable IJ, Chen FK. Intersession test-retest variability of microperimetry in type 2 macular telangiectasia. Transl Vis Sci Technol. 2017;6(6):7. doi.org/10.1167/tvst.6.6.7

10. Uğurlu A, Aslanova M, Cebeci Z, Kır Mercül N. Evaluation of maculopathy in patients using hydroxychloroquine. Turk J Ophthalmol. 2019;49(3):149-153. doi.org/10.4274/tjo.galenos.2018.67864

11. Alibhai AY, Moult EM, Jamil MU, et al. Evaluating the reliability of a microperimetry-based method for assessing visual function in the junctional zone of geographic atrophy lesions. Int J Retina Vitreous. 2025;11(1):1. doi.org/10.1186/s40942-024-00624-7

12. Pfau M, von der Emde L, Dysli C, et al. Determinants of cone and rod functions in geographic atrophy: AI-based structure-function correlation. Am J Ophthalmol. 2020;217:162-173. doi.org/10.1016/j.ajo.2020.04.003

13. Tratnig-Frankl M, Kuchernig L, Birner K, et al. Automated OCT-tailored and same-visit biomarker-targeted microperimetry in geographic atrophy. Sci Rep. 2026;16(1):10830. doi.org/10.1038/s41598-026-45253-2

14. Csaky KG, Patel PJ, Sepah YJ, et al. Microperimetry for geographic atrophy secondary to age-related macular degeneration. Surv Ophthalmol. 2019;64(3):353-364. doi.org/10.1016/j.survophthal.2019.01.014

15. Birner K, Mai J, Boryshchuk D, et al. Exploring trial endpoints in geographic atrophy based on localized functional changes in microperimetry and AI-quantified OCT biomarkers. Invest Ophthalmol Vis Sci. 2026;67(1):22. doi.org/10.1167/iovs.67.1.22

16. Csaky K, Ferris F, Chew EY, Nair P, Cheetham JK, Duncan JL. Report from the NEI/FDA endpoints workshop on age-related macular degeneration and inherited retinal diseases. Invest Ophthalmol Vis Sci. 2017;58(9):3456-3463. doi.org/10.1167/iovs.17-22339

17. Wykoff CC, Holz FG, Chiang A, et al; OAKS, DERBY, and GALE Investigators. Pegcetacoplan treatment for geographic atrophy in age-related macular degeneration over 36 months: data from OAKS, DERBY, and GALE. Am J Ophthalmol. 2025;276:350-364. doi.org/10.1016/j.ajo.2025.04.016